SOL-010/00 - SOL-015/00

PROTECTION PROBES FOR DIESEL ENGINES

Low radiator fluid level alarm device, for the plastic expansion tank (SOL-010) and the metal expansion tank (SOL-015).

FUNCTIONING

SOL-010/00
It becomes active when the module is supplied. When the liquid falls below the level of the electrod, this (after 3 seconds) enables an output which can be used by one of our devices or junction box so as to stop the motor. When the liquid returns to the correct level, the output is deactivated automatically.
SOL-015/00
It becomes active when the module is supplied. When the liquid falls below the level of the rod, the latter (after 3 seconds) enables an output which can be used by one of our devices or junction box so as to stop the motor. When the liquid returns to the correct level, the output is deactivated automatically.

TECHNICAL DATA

- Battery supply 12 and 24 V
- Supply voltage 8÷32 V
- Degree of protection for the electronics:      IP65
- Degree of protection for the terminal board: IP00
  ROD TYPE AST-015/00
- Temperature range -10 ÷ +100°C
- Maximum pressure 1 bar

Type Code
SOL-010/00 00241022
SOL-015/00 00241020

DOWNLOAD

Manual
Instruction and user manual SOL-010/00
Instruction and user manual SOL-015/00

DO YOU NEED MORE INFORMATION?

Contat us